mileto2022newCase report (with review) describing an Italian adult male diagnosed with mpox (monkeypox virus, MPXV) in Milan, Italy (May 2022). Serial sampling from multiple body sites was tested by real-time PCR (Ct values reported) and viral isolation in Vero E6 cells; Table 1/figure CSV provide Ct time series by days from symptom onset for several specimen types (oropharyngeal swab, ulcerated perianal lesion, rectal/anal swab, foot lesion, plasma, seminal fluid, urine).
ct_oropharyngeal_swab
MPXV DNA detection by real-time PCR reported as cycle threshold (Ct) on oropharyngeal swab; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS, targeting variola virus and non-variola Orthopoxvirus species) with MPXV confirmation by a specific homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_ulcerated_perianal_lesion
MPXV DNA detection by real-time PCR reported as Ct on ulcerated perianal lesion swab; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_anorectal_swab
MPXV DNA detection by real-time PCR reported as Ct on anal swab; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_foot_lesion
MPXV DNA detection by real-time PCR reported as Ct on foot lesion sample; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_plasma
MPXV DNA detection by real-time PCR reported as Ct in plasma; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_seminal_fluid
MPXV DNA detection by real-time PCR reported as Ct in seminal fluid; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.
ct_urine
MPXV DNA detection by real-time PCR reported as Ct in urine; Orthopoxvirus screening PCR (RealStar Orthopoxvirus PCR Kit 1.0, altona DIAGNOSTICS) with MPXV confirmation by homemade real-time PCR on screening-positive samples. Ct=40 used as PCR negative cut-off.
Measurements only — no shedding model is fitted to this analyte, usually because it is sampled once per participant, leaving no trajectory to fit, or because nothing was ever detected. Open triangles are non-detects, drawn at the assay's censoring limit. See the modelling methods for what these estimates do and do not support.